What is the main function of the calibration of the side head of the image measuring instrument?

信息来源于:互联网 发布于:2022-04-15

What is the main function of the calibration of the side head of the image measuring instrument? Generally speaking, the calibration of the side head is mainly the index value of the length of the side head, the axial force value of the side head stylus and the half meridian of the side head. The calibration of the side head and standard ball of the two-dimensional imager has a key effect in the whole process of accurate measurement. The application of the side head can automatically align the product workpiece, accurately measure during the sequence, and check after the sequence, which can not only reduce the preparation of the product workpiece in advance time, improve the usable time, and reduce the damage to the product workpiece caused by manual alignment deviation.
The calibration of the side head of the image measuring instrument during the inspection can eliminate the deviation of the total inspection amount caused by the side head. Moreover, the lateral heads can be defined manually or fully automatically. You can delete points and improve point changes according to the reminders to accurately measure the elements, and you can get the specific values of the measured basic elements.

Everyone knows that the daily maintenance of the image measuring instrument is very important, but when the instrument is not working or working, the surrounding environment is also strictly managed. This kind of environment will have a slow shadow box for the instrument, and the service life of the instrument will gradually decrease if you do not pay attention to it. Therefore, users should pay attention to this problem, because the accuracy of the instrument will also be harmed by the environment. Generally, the instrument must be placed in a clean environment, and there are also the following regulations:

1. Reduce oil stains:

The image measuring instrument is a very high-precision instrument, so its slide rail, camera lens, grating ruler and floor plan laminated glass should not be stained with oil, otherwise it will endanger the normal application of the instrument. Usually, you should pay attention not to touch the instrument immediately with unclean hands. It is recommended to bring pure cotton rubber gloves.

2. Clean environment:

The automatic image measuring instrument is a very high-precision instrument, so it cannot be stained with dust. Once the instrument slides, camera lenses, etc. are stained with dust and dirt, it will cause serious harm to the precision and imaging. Therefore, it is necessary to clean up the instrument on time and make the environment as clean as possible. Staff must pay attention to entering and exiting, and it is required to change boots or wear foot covers. And reduce staff access.

本文标签:What is the main function of the calibration of the side head of the image measuring instrument?返回