Precautions for using automatic image measuring instrument

信息来源于:互联网 发布于:2022-04-15

The instrument should be placed in a clean and dry room (room temperature 20°C±5°C, humidity below 60%) to avoid surface contamination of optical parts, rust of metal parts, and dust and debris falling into the motion guide rail, which will affect the performance of the instrument.
5. Lighting

The image measuring instrument cannot be placed in a strong light or direct sunlight environment, otherwise the measurement accuracy of the measuring instrument will be greatly affected.

6. Measuring platform

Please pay special attention to the glass platform when loading and unloading the workpiece. Sometimes the measuring platform will adhere to the water vapor and oil mist layer. Please use a cleaning agent to remove the dirt.

7. Body shell

When not working, please cover with dust cloth. Once the body shell is contaminated, please wipe it with a soft cloth. Because when the fuselage shell is contaminated, although it will not directly affect the measurement accuracy, the pollution may still spread to other parts of the fuselage that affect the measurement accuracy, such as linear slides or platforms.

The maintenance and maintenance of the image measuring instrument are as follows:

1. The image measuring instrument should be placed in a clean and dry room (room temperature 20°C ± 5°C, humidity below 60%) to avoid surface contamination of optical parts, rust of metal parts, dust and debris falling into the moving guide rail, affecting the function of the instrument .

2. The LED light source of the image measuring instrument has a long service life, but when the light bulb burns out, do not disassemble it indiscriminately, and it needs to be replaced by a professional.

3. It has precision parts, such as imaging system, worktable, optical ruler and Z-axis transmission mechanism, which need to be precisely adjusted. All adjustment screws and fastening screws have been fixed. Customers should not disassemble it by themselves. If you have any questions, please inform us. Professionals, if dismantling it by yourself will cause the image measuring instrument to malfunction or reduce its accuracy, it is not covered by the warranty.

4. The transmission mechanism and motion guide rail of the instrument should be lubricated regularly to make the mechanism move smoothly and maintain a good working condition.

5. All electrical connectors of the image measuring instrument should generally not be unplugged. If they have been unplugged, they must be correctly inserted and tightened according to the mark. Improper plugging may affect the function of the instrument at least, and may damage the system at worst.

6. The instrument should be grounded, the power interface behind the base, and the power socket must have a ground wire when using the image measuring instrument.

7. The measurement software on the computer has accurately compensated the error between the worktable and the optical ruler. Please do not change it by yourself, otherwise, wrong measurement results will be produced.

8. The computer is a dedicated computer for imagers, please do not use it for other purposes.

9. If the worktable glass and paint surface are dirty, it can be wiped clean with neutral detergent and water. Never use organic solvent to wipe the paint surface, otherwise, the paint surface will lose its luster.

10. When the instrument is not used for a long time, please close the power system in time.